Products

TEMPEST protective systems

Operation of various devices (for example, computers) may involve generation of signals (TEMPEST) that contain classified information. These signals can be intercepted with the help of special equipment.
Radio interference generators are designed to operate within active information protection systems (APS)enabling information security against data leaks through the TEMPEST channels by generating a broadband noise electromagnetic interference on the edge of the control zone. Such interference noises out the stray radiation of the protected item.

LGS-503
LGS-503

Generator through the 220 V power grid with the frequency of 50 Hz (phase, neutral and ground) and to prevent unauthorized data retrieval through TEMPEST channels, 0.01-2,000 MHz.

Where to buy?

LGS-503 is designed to actively protect informatization equipment against data leaks through the 220 V power grid with the frequency of 50 Hz (phase, neutral and ground) and to prevent unauthorized data retrieval through TEMPEST channels by generating broadband noise electromagnetic interference in the frequency band of 0.01-2,000 MHz.

The device is an average analogous stochastic generator loaded on antennas that are located in the device’s power cord and on the telescopic antennas that are located in the Product's case.

LGS-503 is fed off of the AC circuit with the voltage of 220 V and frequency of 50 Hz. The device can be operated round the clock.

Signal level at power cord plug in the frequency band of 10 - 150 kHz and receiver bandwidth of f=200 Hz
at least 40 dBµV
Signal level at power cord plug in the frequency band of 0.15 - 30 MHz and receiver bandwidth of f=9 kHz
at least 50dBµV
Signal level at power cord plug in the frequency band of 30 - 300 MHz and receiver bandwidth of f=120 kHz
at least 50 dBµV
Generator output signal level n the frequency band of 10 - 150 kHz and receiver bandwidth of f=200 H
at least 50 dBµV
Generator output signal level in the frequency band of 0.15 - 30 MHz and receiver bandwidth of f=9 kHz
at least 50dBµV
Generator output signal level in the frequency band of 30 - 300 MHz and receiver bandwidth of f=120 kHz
at least 50 dBµV
Number of telescopic antennas
2 pos.
Antenna dimensions
at least 55 cm
Power consumption, 220 V / 50 Hz
no more than 40 W
Power voltage
network adapter 220 V, 50 Hz
Operation mod
round the clock
Mean time between failures
at least 10000 h
Average durability
10 years
Dimensions (no antenna)
230x100x45 mm
Weight,(no antenna)
no more than 2 kg